Frequency Response Analyzer
Frequency Response Analyzer HYRZ-903 is an important electrical equipment, its safe and reliable running is extremely important to the power system.
Description
Frequency Response Analyzer HYRZ-903 is an important electrical equipment, its safe and reliable running is extremely important to the power system. The Power Transformer comprehensive parameter tester is a high-precision instrument independently developed by our company specifically for the measurement of transformer sweep frequency response, short circuit impedance, Zero sequence impedance, no-load and load loss parameters of the power transformer (three-phase or single-phase) in the factory test, acceptance test and maintenance routine test. It uses the ARM processor as the core control for sampling, processing and output. Its main features are colorful touch screen display and simple operation. The tester equipped with a high-speed thermal printer, and a storage function designed to facilitate data storage and printing. The tester integrated USB port for PC connection. The PC software can control the tester for testing and data upload VIA this USB port. PC software can convert the saved results or upload results to Word or Excel report. The tester is small size, lightweight and easy to carry. It is very convenient to use in the field, which greatly reduces the labor intensity of the test personnel, and the work efficiency is improved.
The tester can be used to test all kinds of power transformers with different voltage regulator configuration. At the same time, this product can also be used for generator rotor AC impedance test and harmonic test (PC available).
Features
1. Winding deformation test based on IEC standards with sweeping frequency method.
2. It can measure the phase frequency curve and amplitude frequency curve of each winding of the transformer.
4. Analyze the transformer amplitude-frequency curve based on DLT911-2016.
5. Short-circuit impedance method winding deformation test;
6. Measurement parameters of transformer winding short-circuit impedance, short-circuit reactance, short-circuit resistance, three-phase impedance voltage, impedance voltage, voltage RMS value, voltage average value, current, power, power factor, frequency, etc;
7. Analyze the short circuit impedance test results based on IEC60076-5 standard.
8. Transformer no-load and load characteristic test;
9. Measurement of transformer no-load loss, no-load current, load loss, impedance voltage, voltage effective value, voltage average value, current, power, power factor, frequency and other parameters;
10. Automatic correction of short-circuit impedance, no-load and load test results;
11. Analyze the no-load and load test results based on IEC60076 standard;
12. The short-circuit impedance, no-load and load test can be directly measured within the allowable measurement range of the instrument, and a voltage transformer and current transformer can be externally connected when the measurement range is exceeded;
13. Generator rotor AC impedance test;
14. Rotor AC impedance characteristic curve
15. Harmonic test;
16. Simultaneously measure three-phase voltage and current, and display up to 128 harmonics;
17. Built-in non-power-off memory, no-load and load data can be saved 40 groups, generator rotor AC impedance data can be saved 30 groups
Technical Specification
1. For Seep frequency response analysis:
1). Sweeping frequency method to measure winding deformation.
2). Scan frequency range and resolution:
10HZ-1MHZ (DLT911-2016 0.5KHZ interval linear scan)
20HZ-2MHZ (GB/T-1094.18 IEC60076-18:2012 segmented scanning)
10HZ-10MHZ (GB/T-1094.18 IEC60076-18:2012 segmented scanning)
1KHZ -1000KHZ_1.0(Linear scan 1KHZ interval PC side available)
1KHZ -1000KHZ_0.5(linear scan 0.5KHZ interval avaiable for Pc)
1KHZ -2000KHZ_1.0(linear scan 1KHZ interval available for PC)
1KHZ -2000KHZ_0.5(linear scan 0.5KHZ interval available for PC)
100HZ-1000K(Segmented scan PC available 1441 points):
100HZ-1KHZ 5HZ interval 180 points
1KHZ-10KHZ 50HZ interval 180 points
10KHZ-100KHZ 500HZ interval 180 points
100KHZ-1000KHZ 1KHZ interval 901 points
100HZ-2000K(Segmented scan PC available 2441 points)
100HZ-1KHZ 5HZ interval 180 points
1KHZ-10KHZ 50HZ interval 180 points
10KHZ-100KHZ 500HZ interval 180 points
100KHZ-1000KHZ 1KHZ interval 900 points
1000KHZ-2000KHZ 1KHZ interval 1001 Points
3). Amplitude measurement range: (-100dB) - (+20dB)
4). Amplitude measurement accuracy: (-40dB) - (+20dB) 0.2dB
(-60dB) - (-40dB) 0.5dB
(-80dB) - (-60dB) 1.0dB
5). Angle measurement range: (-180°) - (+180°) (10HZ-2MHZ)
6). Scan frequency accuracy: less than 0.01%
7). Signal input impedance:
greater than 1M Ω(DLT911-2016)
50 Ω(GB/T-1094.18 IEC60076-18:2012)
8). Signal output impedance: 50 Ω.
9). Maximum output voltage:20VPP
10). Same-phase test repetition rate: 99.5%.
2 .For impedance and load test
1). Short-circuit impedance method winding deformation, transformer no load and load, rotor AC impedance measurement range:
Voltage measurement range: AC 0~600V
Current measurement range: AC 0~120A
Frequency measurement range: 45~65Hz
2) Measurement accuracy:
Frequency: 0.2%reading
Active power:
For cosφ>0.1 error <0.5%reading±2 digits
For cosφ<0.1 error <1.0%reading±2 digits
Reactive power error<0.2%reading±2 digits
Power factor error<0.5%reading±2 digits
Voltage and current error< 0.2%reading±2 digits
3. Working conditions
Power supply voltage:AC220V±10%
Power supply frequency:45-65Hz
Power dissipation:≤100w
Ambient temperature:0~50℃
Ambient humidity:≤90%RH
Host size:520290220mm3 Weight:12kg