Transformer Turn Ratio Tester
video
Transformer Turn Ratio Tester

Transformer Turn Ratio Tester

Transformer Turn Ratio Tester HYBC-901B is an instrument used ratio and phase angle measurement of power transformer and voltage transformer. The tester inject three-phase voltage to the primary side of transformer and measure the inducted voltage from secondary of transformer and then calculate the turns ratio, voltage ratio, phase angle difference between primary side to secondary.

Description

Transformer Turn Ratio Tester HYBC-901B is an instrument used ratio and phase angle measurement of power transformer and voltage transformer. The tester inject three-phase voltage to the primary side of transformer and measure the inducted voltage from secondary of transformer and then calculate the turns ratio, voltage ratio, phase angle difference between primary side to secondary.

 

Features

 

1.Voltage ratio measurement of three-phase or single-phase power transformer.
2.Voltage ratio measurement of three-phase or single-phase voltage transformer.
3.Turns ratio measurement of three-phase or single-phase power transformer and voltage transformer.
4.Vector group test of three-phase power transformer.
5.Tap position detection of three phase power transformer.
6.Phase angle difference measurement of power transformer and voltage transformer.
7.Micro printer integrated for test results print.
8.USB interface for test results data upload
9.Making word report for uploaded test results with PC software.

 

Technical Specification

1.Voltage ratio and turns ratio measurement range:1-10000
2.Ratio measurement error: 1-1000 error<0.2%, 1000-1000 error<0.5%
3.Repeatable error for ratio test <0.05%
4.Vector group measurement: 1-12

5.Phase angle measurement range: 0-360 degree. Error <0.5 degree.
6.Test voltage: AC 0-120V per phase. Maximum output current 200mA per phase.
7.Distortion of test voltage less than 1%.
8.Excitation current indication range:0-200mA. Error <1%

9.Supported connection mode for three-phase transformer: DY, YD, DD, YY,ZN
10.Maximum storage capability: 200 groups
11.Power supply LI battery: 12V 15000mAH. Once charge can working more than 10 hours during on site test.

12.Charger power supply AC 100-230V 45-65Hz.
13.Size:400*350*200mm. Weight <10kg
14.Working temperature: 0-50 degree. Humidity <90%

 

Hot Tags: transformer turn ratio tester, China transformer turn ratio tester manufacturers, suppliers, factory, 4 Pole Earth Resistance Tester, Frequency Response Analyzer, Handheld Digital Insulation Resistance Tester 5KV 10KV, On Load Tap Changer Analyzer, Transformer No Load And Load Tester, transformer tester